Minelab F1A4 Manual de Serviço Página 22

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 21
F1A4 Field Service Manual – Level 1 and Level 2 Maintenance
Page 22
Release the switch so that it returns to the SEARCH position. Continue to
move the GB Test Piece up and down, approximately 25 to 100mm from the Coil.
The F1A4 should not respond to the test piece. If a response is heard check that
there is no metal on the technician or the GB Test Piece and repeat the test.
5.1.3.2 Troubleshooting
If a response is still heard repeat the test. If a response is still heard, replace
the coil and repeat the test. If a response is still heard, remove the 6 screws from
the front panel, pull the front panel away from the case, and use a multimeter to
check the circuit of the Off/Search/Balance switch (refer Section 7 for switch circuit
details). If the switch does not measure correctly, the switch is defective, go to 5.2.2
for the
Off/Search/Balance
switch replacement procedure. If the switch measures
OK, check wiring from the PCB to the Off/Search/Balance switch and repair as
necessary If the wiring if found to be OK, the PCB is defective. Go to 5.2.4 for the
PCB replacement procedure.
5.1.4 Noise Cancel Troubleshooting
5.1.4.1 Noise Cancel Test
Momentarily press the NOISE CANCEL button.
The F1A4 should immediately “beep”.
After 70 seconds the F1A4 should “beep” four times:
BEEP BEEP BEEP BEEP
5.1.4.2 Troubleshooting
If the correct tones are not heard during the above procedure, remove the 6
screws from the front panel, pull the front panel away from the case, and check the
wiring from the PCB to the Front Panel and repair as necessary (also check the
ribbon cable for continuity). If there are still no tones, go to 5.2.5 for Front Panel
replacement procedure. If the Front Panel has already been replaced the PCB is
defective. Go to 5.2.4 for the PCB replacement procedure.
Vista de página 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 35 36

Comentários a estes Manuais

Sem comentários